Latest avg IR
3.133 mΩ
2026-10-18
Fleet · C2-P2 · CNHL V2 6S ~1300 Black · 1300 mAh · C2
Parallel Go: on the C2 board | In service
Rules v7: self-discharge check passed (1 mV in 9 days). Watch cleared.
Parallel Go: on the C2 board | In service · 16 storage charges
Status call 2026-10-18 · charged in parallel
Purchase — · price — · vendor —
Latest avg IR
3.133 mΩ
2026-10-18
Spread
1.0 mΩ
Go on this spread alone. Caution starts at 2.0 mΩ, watch note at 3.0 mΩ or more. The status call is separate.
Start floor
3706 mV
Floor watch 3600 mV
Last storage
2026-10-18
Low-cell gap 21 mV · rest 22.323 V · S_R 18.8 mΩ
Not a storage night
This full charge isn't the latest IR, a fleet or series mean, or a Rule B night. Its start voltage, floor, gap and rest come from the charge start and aren't shown here.
| Session | Avg (mΩ) | Spread (mΩ) | S_R (mΩ) |
|---|---|---|---|
| 2026-10-18-charge | 3.283 | 1.4 | 20.2 |
Not a parallel charge
This individual top-up is the day-0 baseline. It isn't the latest IR, a fleet or series mean, or a Rule B night.
| Night | Avg (mΩ) | Spread (mΩ) | S_R (mΩ) | Floor (mV) | Gap (mV) |
|---|---|---|---|---|---|
| 2026-10-09-restday0 | 3.133 | 1.6 | 18.8 | 3792 | 5 |
7-day rest
History
undated · Commissioned → C2-P2
Commissioned into C2-P2, its first night with measurements. Earlier catalog nights aren't in this record. The pack ID was assigned on 2026-10-08.
2026-10-09 · Rest test started · C2-P2 → C2-P2
7-day rest test cycle 1 (suspect Cell 6); day-0 = storage_end of short DX8 top-up; 7-day reading due 2026-10-16; Rules v3
2026-10-09 · Entered Rest pool · C2-P2 → C2-P2
Off every board until the 7-day reading on 2026-10-16.
2026-10-17 · Left Rest pool · C2-P2 → C2-P2
Left the rest pool under rules v6 (approved 2026-10-17): the rest pool is retired. Back in rotation at its home slot (DX8-2 Channel 1, after C2-P1) and on the C2 parallel board from its next storage night. Rest test RT-008-1 completes in place from the first reading of that storage log, if it has not flown since 2026-10-09.
Calls
2026-09-22C2-P2
Watch HARD; OK now
spread Go (28); spread history (prior ≥50)
2026-09-26-eveC2-P2
Caution floor EYE
floor 3596 (<3600); imb 101 not SD≥150; still ON; Cell3 pack-min FP PASS
2026-09-27C2-P2
Caution spr
spread 44 Caution; Cell3 pack-min FP PASS; floor 3684 OK (eve EYE 3596 cleared); ON
2026-09-30C2-P2
Caution floor EYE
floor 3597 (<3600); spread 26 Go (was 44); Cell3 pack-min FP PASS; imb 103 not SD; ON
2026-10-09C2-P2
Parallel Caution (reduced current) | Watch; rest test Cell 6 cycle 1 started 2026-10-09
Rules v3: Cell6 gap >=60 mV on 2 of last 3 (last 3 = 94/19/98 mV); >=100 on 3/13; floor 3597 mV. Evidence (last 2026-09-30: IR avg 3.22 spread 1.2 mOhm, S_R 19.3; floor 3597 (Cell6); low-cell gap 98 mV)
2026-10-09C2-P2
Parallel Off (Rest pool) | Watch; rest test RT-008-1, 7-day reading due 2026-10-16; not charged during test
Rest pool (owner decision 2026-10-09): off all parallel boards and not charged until the 7-day reading; returns by rest-test result under Rules v3 (PASS/BORDERLINE/FAIL + service-tier rules). Status/grouping change only, no new measurement.
2026-10-09-restday0C2-P2
unchanged (factual measurement)
rest-test day-0 measurement 2026-10-09-restday0: start floor 3792 mV (Cell1), imbalance 7 mV, low-cell gap 5 mV, rest 22.774 V; IR avg 3.133 spread 1.6 mOhm, S_R 18.8; short top-up from near storage, rest duration unknown - not evidence for/against self-discharge; 7-day reading due 2026-10-16
2026-10-17C2-P2
Parallel Go: on the C2 board | Watch (rest test RT-008-1 completes in place)
Back in rotation under rules v6 (approved 2026-10-17): the rest pool is retired. Returns to its home slot (DX8-2 Channel 1, after C2-P1) and to the C2 parallel board on its next storage night. Rest test RT-008-1 (Cell 6) completes in place from the first reading of that storage log, if it has not flown since 2026-10-09; the drop is scaled to 7 days (pass 10 mV or less, borderline 10 to 30 mV, fail over 30 mV, and a fail is a note). Watch is a note only.
2026-10-17C2-P2
Parallel Go: on the C2 board | Watch (self-discharge check RT-008-1)
Re-graded under rules v7. No pull sign in the data. The open rest test RT-008-1 (Cell 6) is now the self-discharge check: it completes from the first line of its next storage log if the pack has not flown since 2026-10-09. The lowest cell and low-cell gap are performance notes.
2026-10-18C2-P2
Parallel Go: on the C2 board | In service
Rules v7: self-discharge check passed (1 mV in 9 days). Watch cleared.
2026-10-18
Color scale is this snapshot only.
Every night for this pack
The line follows this pack by serial, under whatever label it had that night. Every recorded reading is joined to the next one, including charge-alone nights and nights from before a move. A night it wasn't charged, between two readings, shows as a faint dotted line with no value. Nothing is drawn before the first reading or after the last, and a pack with only its first reading is a single point. A star on the night label means a partial night, which is a separate thing.
dotted = not charged
CNHL-2026-008 per-cell internal resistance, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-26, 2026-10-17, 2026-10-23, 2026-10-24.
Rules v7
dotted = not charged
CNHL-2026-008 intra-pack spread with watch-note guides, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-26, 2026-10-17, 2026-10-23, 2026-10-24.
Watch line
dotted = not charged
CNHL-2026-008 start floor with a 3600 millivolt watch line Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-26, 2026-10-17, 2026-10-23, 2026-10-24.
All measured nights
Each night is one row. A dash means this pack wasn't charged that night. On the line chart, a faint dotted join connects the readings on either side, with no value filled in. Nothing is drawn before the first reading or after the last.
Cell, average and spread figures are in mΩ. A Rest pool night is labeled Rest pool: the pack was off every board and wasn't charged. Not charged means the pack was in service and wasn't logged that night. On the charts, a faint dotted line joins the readings on either side of that night, and that night has no value. Nothing is drawn before the first reading or after the last. A star is a partial night, which is different. Nights before this pack was commissioned aren't marked, and readings from before a move stay on this line.
| Night | Label | Cell 1 (mΩ) | Cell 2 (mΩ) | Cell 3 (mΩ) | Cell 4 (mΩ) | Cell 5 (mΩ) | Cell 6 (mΩ) | Avg (mΩ) | Spread (mΩ) | Floor (mV) |
|---|---|---|---|---|---|---|---|---|---|---|
| undated | C2-P2 | 3.1 | 3.1 | 4.1 | 3.2 | 3.7 | 4.1 | 3.55 | 1.0 | 3547 |
| undated | C2-P2 | 3.0 | 3.0 | 4.3 | 3.2 | 2.4 | 3.1 | 3.167 | 1.9 | 3557 |
| undated | C2-P2 | 2.5 | 1.8 | 2.7 | 2.6 | 3.0 | 3.25 | 2.642 | 1.45 | 3606 |
| undated | C2-P2 | 4.0 | 3.1 | 1.7 | 2.1 | 1.0 | 4.0 | 2.65 | 3.0 | 3703 |
| undated | C2-P2 | 3.0 | 3.1 | 3.5 | 3.2 | 2.4 | 3.0 | 3.033 | 1.1 | 3606 |
| undated | C2-P2 | 3.2 | 2.0 | 3.5 | 3.1 | 1.0 | 1.0 | 2.3 | 2.5 | 3651 |
| undated | C2-P2 | 3.2 | 2.9 | 3.5 | 3.2 | 3.1 | 3.1 | 3.167 | 0.6 | 3621 |
| undated | C2-P2 | 3.1 | 3.0 | 3.2 | 3.0 | 3.1 | 2.5 | 2.983 | 0.7 | 3695 |
| undated | C2-P2 | 3.3 | 3.1 | 3.7 | 2.5 | 1.7 | 3.2 | 2.917 | 2.0 | 3545 |
| undated | C2-P2 | 3.2 | 2.9 | 2.9 | 2.7 | 1.7 | 1.7 | 2.517 | 1.5 | 3655 |
| 2026-09-26* | C2-P2 | Not charged | ||||||||
| 2026-09-26-eve | C2-P2 | 2.6 | 2.2 | 3.6 | 2.7 | 3.1 | 2.4 | 2.767 | 1.4 | 3596 |
| 2026-09-27 | C2-P2 | 3.4 | 2.2 | 3.6 | 3.3 | 2.2 | 3.1 | 2.967 | 1.4 | 3684 |
| 2026-09-30* | C2-P2 | 3.2 | 2.9 | 4.1 | 3.1 | 3.0 | 3.0 | 3.217 | 1.2 | 3597 |
| 2026-10-09* | C2-P2 | Rest pool | ||||||||
| 2026-10-10* | C2-P2 | Rest pool | ||||||||
| 2026-10-11-charge* | C2-P2 | Rest pool | ||||||||
| 2026-10-11* | C2-P2 | Rest pool | ||||||||
| 2026-10-14-charge | C2-P2 | Rest pool | ||||||||
| 2026-10-14 | C2-P2 | Rest pool | ||||||||
| 2026-10-16 | C2-P2 | Rest pool | ||||||||
| 2026-10-17-charge* | C2-P2 | Rest pool | ||||||||
| 2026-10-17 | C2-P2 | Not charged | ||||||||
| 2026-10-18 | C2-P2 | 3.3 | 2.9 | 3.6 | 3.2 | 3.2 | 2.6 | 3.133 | 1.0 | 3706 |
| 2026-10-23* | C2-P2 | Not charged | ||||||||
| 2026-10-24* | C2-P2 | Not charged | ||||||||