Fleet · C1-P5 · CNHL V2 6S ~1300 Black · 1300 mAh · C1

C1-P5 · CNHL-2026-005

GO

Parallel Go: on the C1 board | In service

Re-graded under rules v7: the low Cell 4 is a performance note, not a pull or charge-alone reason. Advisory: on 2026-10-11 its Cell 4 started 109 mV from C1-P6 Cell 4, so check resting voltage before connecting.

Parallel Go: on the C1 board | In service · 18 storage charges

Status call 2026-10-17 · charged in parallel

Purchase — · price — · vendor —

Latest avg IR

2.75 mΩ

2026-10-18

Spread

0.8 mΩ

Go on this spread alone. Caution starts at 2.0 mΩ, watch note at 3.0 mΩ or more. The status call is separate.

Start floor

3683 mV

Floor watch 3600 mV

Last storage

2026-10-18

Low-cell gap 6 mV · rest 22.126 V · S_R 16.5 mΩ

Not a storage night

Charge run

This full charge isn't the latest IR, a fleet or series mean, or a Rule B night. Its start voltage, floor, gap and rest come from the charge start and aren't shown here.

SessionAvg (mΩ)Spread (mΩ)S_R (mΩ)
2026-10-11-charge3.0170.918.1

History

Slot history

  1. undated · Commissioned → C1-P5

    Commissioned into C1-P5, its first night with measurements. Earlier catalog nights aren't in this record. The pack ID was assigned on 2026-10-08.

Calls

Status over time

  1. 2026-09-22C1-P5

    Ok

    spread Go (38), near Caution line

  2. 2026-09-26C1-P5

    Go

    spread 28

  3. 2026-09-26-eveC1-P5

    Go

    spread 22

  4. 2026-09-27C1-P5

    Off tonight

    floor 3539 EYE + low rest 21.523 V; spread 33 Go; imb 71 not SD; off for rest-Δ GO (with P5 Δ≈0.522 CAUTION); report per-pack table: CAUTION floor EYE + low rest

  5. 2026-10-08C1-P5

    Watch

    from 2026-09-27: floor 3539 mV EYE, lowest rest 21.523 V, spread 33; charge_mode individual; Rule B N/A

  6. 2026-10-09C1-P5

    Parallel Caution; charged INDIVIDUALLY until one clean night, then GO | Watch

    Rules v3: 2026-09-27 floor 3539 mV Cell4 (<3600), gap 61 mV. Evidence (last 2026-09-27: IR avg 2.98 spread 0.5 mOhm, S_R 17.9; floor 3539 (Cell4); low-cell gap 61 mV)

  7. 2026-10-10C1-P5

    Parallel Caution; charged INDIVIDUALLY until one clean night, then GO | Watch

    Rules v3: NOT a clean night: floor 3594 mV on usual low Cell4 (<3600) and low-cell gap 77 mV (≥60 on 2 of last 3: 30/61/77) → stays CAUTION, individual, Watch; Rule B N/A (rest 21.924 V vs board 22.007–22.142). Evidence (2026-10-10: IR avg 2.92 spread 0.5 mOhm, S_R 17.5; floor 3594 (Cell4); low-cell gap 77 mV; rest 21.924 V)

  8. 2026-10-11-chargeC1-P5

    Parallel Caution; charged INDIVIDUALLY until one clean storage night | Watch (unchanged)

    Charge run (not a storage night; no clean-night credit). IR under charge: 2.4/3.2/3.1/3.3/3.1/3.0 mOhm, avg 3.017, spread 0.9, S_R 18.1; no IR trigger on the run median; start-of-charge cells were high and settled (screen m00:20 Cell6 4.8, Cell2 4.0, Cell4 4.5 -> 3.0/3.1/3.0 by m26; instant spread 2.4 at start), a settling effect not a cell signal; consistent with storage history (avg ~2.6-3.0, S_R 15-19)

  9. 2026-10-11C1-P5

    Parallel Go (rejoins C1 board; conditional on Rule B) | Watch

    Rules v3: CLEAN NIGHT: floor 3620 >=3600 on usual low Cell4, gap 50 <60, spread 1.5 <2.0, no ratio trigger -> CAUTION->GO, charge_mode individual->parallel; stays on Watch for now. Rest 21.963 V is 0.198-0.384 V below the C1 board (P2/P3/P6), so for the next night it joins only if within 0.30 V. Evidence (2026-10-11: IR 2.0/2.8/3.1/2.5/1.6/2.9 mOhm, avg 2.48, spread 1.5, max/median 1.17, S_R 14.9; floor 3620 (Cell4); low-cell gap 50 mV; rest 21.963 V)

  10. 2026-10-11C1-P5

    Parallel Go (conditional on Rule B) | Watch

    Go: clean storage night on 2026-10-11 (floor 3620 mV on Cell 4, low-cell gap 50 mV); back on the C1 board if its rest V is within 0.30 V of the other board packs, otherwise it charges alone. Last 3 storage-night gaps: 61 (2026-09-27), 77 (2026-10-10), 50 (2026-10-11) mV; stays on Watch.

  11. 2026-10-16C1-P5

    Parallel Go: on the C1 board | Watch

    Under the charge rules from 2026-10-16, every pack charges on its own parallel board; a watch note does not take a pack off, and the only check before connecting is rest voltage within 0.60 V (0.1 V per cell). On 2026-10-11 the C1 board charged C1-P2, C1-P3 and C1-P6 together (0.186 V apart); C1-P5 charged alone that night. With C1-P5 added, the latest rest V of all four C1 packs were 0.384 V apart, inside 0.60 V. Watch note: low Cell 4 (started 61, 77 and 50 mV below the other cells on 2026-09-27, 2026-10-10 and 2026-10-11; lowest cell 3539 mV on 2026-09-27).

  12. 2026-10-17C1-P5

    Parallel Go: on the C1 board | In service

    Re-graded under rules v7: the low Cell 4 is a performance note, not a pull or charge-alone reason. Advisory: on 2026-10-11 its Cell 4 started 109 mV from C1-P6 Cell 4, so check resting voltage before connecting.

2026-10-18

Latest cell IR

2.3 mΩ3.1 mΩ

Color scale is this snapshot only.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
C1-P5
3.1mΩ
2.3mΩ
3.0mΩ
2.6mΩ
2.4mΩ
3.1mΩ

Every night for this pack

Cell IR across nights

The line follows this pack by serial, under whatever label it had that night. Every recorded reading is joined to the next one, including charge-alone nights and nights from before a move. A night it wasn't charged, between two readings, shows as a faint dotted line with no value. Nothing is drawn before the first reading or after the last, and a pack with only its first reading is a single point. A star on the night label means a partial night, which is a separate thing.

dotted = not charged

CNHL-2026-005 per-cell internal resistance, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-23, 2026-10-24.

1.50 mΩ2.00 mΩ2.50 mΩ3.00 mΩ3.50 mΩ4.00 mΩ

Rules v7

Intra-pack spread

dotted = not charged

CNHL-2026-005 intra-pack spread with watch-note guides, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-23, 2026-10-24.

0.00 mΩ1.00 mΩ2.00 mΩ3.00 mΩ
Watch note ≥ 2.0 mΩWatch note, look first ≥ 3.0 mΩ

Watch line

Start floor

dotted = not charged

CNHL-2026-005 start floor with a 3600 millivolt watch line Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-23, 2026-10-24.

3550 mV3600 mV3650 mV3700 mV3750 mV
3600 mV watch

All measured nights

Cell IR by night

1.6 mΩ4.1 mΩ

Each night is one row. A dash means this pack wasn't charged that night. On the line chart, a faint dotted join connects the readings on either side, with no value filled in. Nothing is drawn before the first reading or after the last.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
undated
4.1mΩ
2.0mΩ
3.5mΩ
3.5mΩ
2.4mΩ
3.2mΩ
undated
2.5mΩ
2.3mΩ
3.1mΩ
3.0mΩ
2.0mΩ
3.1mΩ
undated
2.3mΩ
2.8mΩ
3.1mΩ
3.1mΩ
2.5mΩ
2.0mΩ
undated
2.2mΩ
2.5mΩ
2.6mΩ
2.5mΩ
3.3mΩ
2.5mΩ
undated
2.8mΩ
2.8mΩ
2.8mΩ
3.1mΩ
3.1mΩ
2.9mΩ
undated
2.2mΩ
2.7mΩ
2.4mΩ
2.6mΩ
2.1mΩ
3.2mΩ
undated
3.1mΩ
2.7mΩ
2.7mΩ
3.1mΩ
2.9mΩ
2.1mΩ
undated
3.2mΩ
2.9mΩ
2.9mΩ
3.1mΩ
2.9mΩ
2.9mΩ
undated
3.0mΩ
2.5mΩ
3.2mΩ
3.2mΩ
3.0mΩ
2.9mΩ
undated
3.2mΩ
2.5mΩ
2.8mΩ
2.4mΩ
3.0mΩ
3.0mΩ
09-26*
2.5mΩ
2.3mΩ
2.8mΩ
2.4mΩ
2.8mΩ
2.8mΩ
09-26e
3.1mΩ
2.5mΩ
3.2mΩ
3.2mΩ
3.0mΩ
3.1mΩ
09-27
3.0mΩ
3.0mΩ
3.1mΩ
3.1mΩ
2.6mΩ
3.1mΩ
09-30*
—
—
—
—
—
—
10-09*
—
—
—
—
—
—
10-10*
2.9mΩ
2.7mΩ
2.8mΩ
3.2mΩ
2.9mΩ
3.0mΩ
10-11*
2.0mΩ
2.8mΩ
3.1mΩ
2.5mΩ
1.6mΩ
2.9mΩ
10-14
—
—
—
—
—
—
10-16
—
—
—
—
—
—
10-17
2.2mΩ
3.0mΩ
3.1mΩ
2.9mΩ
2.8mΩ
3.1mΩ
10-18
3.1mΩ
2.3mΩ
3.0mΩ
2.6mΩ
2.4mΩ
3.1mΩ
10-23*
—
—
—
—
—
—
10-24*
—
—
—
—
—
—
Night table

Cell, average and spread figures are in mΩ. A Rest pool night is labeled Rest pool: the pack was off every board and wasn't charged. Not charged means the pack was in service and wasn't logged that night. On the charts, a faint dotted line joins the readings on either side of that night, and that night has no value. Nothing is drawn before the first reading or after the last. A star is a partial night, which is different. Nights before this pack was commissioned aren't marked, and readings from before a move stay on this line.

NightLabelCell 1 (mΩ)Cell 2 (mΩ)Cell 3 (mΩ)Cell 4 (mΩ)Cell 5 (mΩ)Cell 6 (mΩ)Avg (mΩ)Spread (mΩ)Floor (mV)
undatedC1-P54.12.03.53.52.43.23.1172.13648
undatedC1-P52.52.33.13.02.03.12.6671.13637
undatedC1-P52.32.83.13.12.52.02.6331.13592
undatedC1-P52.22.52.62.53.32.52.61.13702
undatedC1-P52.82.82.83.13.12.92.9170.33686
undatedC1-P52.22.72.42.62.13.22.5331.13665
undatedC1-P53.12.72.73.12.92.12.7671.03681
undatedC1-P53.22.92.93.12.92.92.9830.33598
undatedC1-P53.02.53.23.23.02.92.9670.73646
undatedC1-P53.22.52.82.43.03.02.8170.83658
2026-09-26*C1-P52.52.32.82.42.82.82.60.53648
2026-09-26-eveC1-P53.12.53.23.23.03.13.0170.73663
2026-09-27C1-P53.03.03.13.12.63.12.9830.53539
2026-09-30*C1-P5Not charged
2026-10-09*C1-P5Not charged
2026-10-10*C1-P52.92.72.83.22.93.02.9170.53594
2026-10-11*C1-P52.02.83.12.51.62.92.4831.53620
2026-10-14C1-P5Not charged
2026-10-16C1-P5Not charged
2026-10-17C1-P52.23.03.12.92.83.12.850.93762
2026-10-18C1-P53.12.33.02.62.43.12.750.83683
2026-10-23*C1-P5Not charged
2026-10-24*C1-P5Not charged