Fleet · C1-P1 · CNHL V2 6S ~1300 Black · 1300 mAh · C1

C1-P1 · CNHL-2026-001

GO

Parallel Go: on the C1 board | In service (watch)

Re-graded under rules v7 with storage-end advisories; supersedes the earlier rows. C1-P1 charges on DX8-1 Channel 1 and joins the C1 parallel board from the next storage night. Rest test RT-001-1 passed on 2026-10-17. Storage night 2026-10-17: no pull sign. Cell 6 started 172 mV below its other cells after flying: a performance note, and Cell 6 stays a watch note. At the end of its storage run it was within 0.60 V of the other C1 packs and within 0.10 V cell by cell, so it has no board advisory.

Parallel Go: on the C1 board | In service (watch) · 17 storage charges

Status call 2026-10-17 · charged in parallel

Purchase — · price — · vendor —

Latest avg IR

2.733 mΩ

2026-10-18

Spread

0.5 mΩ

Go on this spread alone. Caution starts at 2.0 mΩ, watch note at 3.0 mΩ or more. The status call is separate.

Start floor

3708 mV

Floor watch 3600 mV

Last storage

2026-10-18

Low-cell gap 10 mV · rest 22.289 V · S_R 16.4 mΩ

Not a storage night

Charge run

This full charge isn't the latest IR, a fleet or series mean, or a Rule B night. Its start voltage, floor, gap and rest come from the charge start and aren't shown here.

SessionAvg (mΩ)Spread (mΩ)S_R (mΩ)
2026-10-17-charge3.0830.318.5

7-day rest

Rest test

  • Cell 6 started 2026-10-09. Day-0 baseline 2026-10-09. 7-day reading due 2026-10-16. Read 2026-10-17: PASS (2 mV extra drop).

History

Slot history

  1. undated · Commissioned → C1-P1

    Commissioned into C1-P1, its first night with measurements. Earlier catalog nights aren't in this record. The pack ID was assigned on 2026-10-08.

  2. 2026-10-09 · Rest test started · C1-P1 → C1-P1

    7-day rest test cycle 1 (suspect Cell 6); day-0 = storage_end of short DX8 top-up; 7-day reading due 2026-10-16; Rules v3

  3. 2026-10-09 · Entered Rest pool · C1-P1 → C1-P1

    Off every board until the 7-day reading on 2026-10-16.

  4. 2026-10-17 · Left Rest pool · C1-P1 → C1-P1

    Left the Rest pool: rest test RT-001-1 passed (Cell 6 dropped 13 mV against a middle value of 11 mV for the other cells, so 2 mV extra, within the 10 mV limit). Back to individual charging: charged on its own, never on a parallel board. This is pass 1 of the 3 in a row it needs to leave individual charging, followed by 3 GO nights on a parallel board.

Calls

Status over time

  1. undatedC1-P1

    Eye

    Cell6 arrived 3.507 V (190 mV imbalance); IR did not explode; self-discharge watch

  2. 2026-09-22C1-P1

    Do NOT PARALLEL / REPLACE path

    spread Caution (45); self-discharge Cell6 (floor 3.507 V, chronic); off C1 board

  3. 2026-09-26C1-P1

    Pull / OFF

    chronic Cell6 SD (floor 3509, imb 184); spread 29 Go — off is SD

  4. 2026-09-26-eveC1-P1

    Pull / OFF

    chronic Cell6 SD (floor 3543, imb 155); spread 33 Go — off is SD

  5. 2026-09-27C1-P1

    Pull / OFF

    chronic Cell6 SD (floor 3509, imb 191), worse vs eve 3543/155; spread 42 Caution — off is SD

  6. 2026-10-17C1-P1

    Parallel Go: on the C1 board | In service (watch)

    Re-graded under rules v7 with storage-end advisories; supersedes the earlier rows. C1-P1 charges on DX8-1 Channel 1 and joins the C1 parallel board from the next storage night. Rest test RT-001-1 passed on 2026-10-17. Storage night 2026-10-17: no pull sign. Cell 6 started 172 mV below its other cells after flying: a performance note, and Cell 6 stays a watch note. At the end of its storage run it was within 0.60 V of the other C1 packs and within 0.10 V cell by cell, so it has no board advisory.

2026-10-18

Latest cell IR

2.4 mΩ2.9 mΩ

Color scale is this snapshot only.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
C1-P1
2.9mΩ
2.8mΩ
2.5mΩ
2.4mΩ
2.9mΩ
2.9mΩ

Every night for this pack

Cell IR across nights

The line follows this pack by serial, under whatever label it had that night. Every recorded reading is joined to the next one, including charge-alone nights and nights from before a move. A night it wasn't charged, between two readings, shows as a faint dotted line with no value. Nothing is drawn before the first reading or after the last, and a pack with only its first reading is a single point. A star on the night label means a partial night, which is a separate thing.

dotted = not charged

CNHL-2026-001 per-cell internal resistance, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-23, 2026-10-24.

1.00 mΩ1.50 mΩ2.00 mΩ2.50 mΩ3.00 mΩ

Rules v7

Intra-pack spread

dotted = not charged

CNHL-2026-001 intra-pack spread with watch-note guides, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-23, 2026-10-24.

0.00 mΩ1.00 mΩ2.00 mΩ3.00 mΩ
Watch note ≥ 2.0 mΩWatch note, look first ≥ 3.0 mΩ

Watch line

Start floor

dotted = not charged

CNHL-2026-001 start floor with a 3600 millivolt watch line Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-23, 2026-10-24.

3500 mV3600 mV3700 mV3800 mV
3600 mV watch

All measured nights

Cell IR by night

1.1 mΩ3.2 mΩ

Each night is one row. A dash means this pack wasn't charged that night. On the line chart, a faint dotted join connects the readings on either side, with no value filled in. Nothing is drawn before the first reading or after the last.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
undated
1.1mΩ
2.3mΩ
2.5mΩ
2.1mΩ
1.6mΩ
2.6mΩ
undated
1.7mΩ
2.3mΩ
2.2mΩ
2.1mΩ
2.9mΩ
2.6mΩ
undated
2.3mΩ
1.8mΩ
2.4mΩ
2.3mΩ
2.0mΩ
2.4mΩ
undated
1.6mΩ
1.7mΩ
2.1mΩ
2.0mΩ
2.3mΩ
1.3mΩ
undated
2.5mΩ
2.5mΩ
2.6mΩ
2.3mΩ
2.7mΩ
3.1mΩ
undated
1.9mΩ
2.5mΩ
2.3mΩ
2.6mΩ
2.7mΩ
2.6mΩ
undated
2.4mΩ
2.0mΩ
2.1mΩ
2.5mΩ
2.5mΩ
2.4mΩ
undated
2.8mΩ
2.7mΩ
2.5mΩ
2.7mΩ
3.0mΩ
2.95mΩ
undated
1.8mΩ
2.6mΩ
2.6mΩ
2.9mΩ
3.0mΩ
2.7mΩ
undated
3.1mΩ
1.4mΩ
1.8mΩ
2.6mΩ
1.3mΩ
2.2mΩ
09-26*
1.9mΩ
2.1mΩ
2.2mΩ
1.7mΩ
2.0mΩ
3.0mΩ
09-26e
1.4mΩ
1.8mΩ
2.4mΩ
1.9mΩ
2.4mΩ
2.4mΩ
09-27
3.1mΩ
2.5mΩ
2.6mΩ
3.1mΩ
3.1mΩ
3.2mΩ
09-30*
—
—
—
—
—
—
10-09*
3.2mΩ
2.9mΩ
2.5mΩ
2.2mΩ
3.0mΩ
2.8mΩ
10-10*
—
—
—
—
—
—
10-11*
—
—
—
—
—
—
10-14
—
—
—
—
—
—
10-16
—
—
—
—
—
—
10-17
2.0mΩ
2.5mΩ
2.7mΩ
2.1mΩ
2.5mΩ
2.6mΩ
10-18
2.9mΩ
2.8mΩ
2.5mΩ
2.4mΩ
2.9mΩ
2.9mΩ
10-23*
—
—
—
—
—
—
10-24*
—
—
—
—
—
—
Night table

Cell, average and spread figures are in mΩ. A Rest pool night is labeled Rest pool: the pack was off every board and wasn't charged. Not charged means the pack was in service and wasn't logged that night. On the charts, a faint dotted line joins the readings on either side of that night, and that night has no value. Nothing is drawn before the first reading or after the last. A star is a partial night, which is different. Nights before this pack was commissioned aren't marked, and readings from before a move stay on this line.

NightLabelCell 1 (mΩ)Cell 2 (mΩ)Cell 3 (mΩ)Cell 4 (mΩ)Cell 5 (mΩ)Cell 6 (mΩ)Avg (mΩ)Spread (mΩ)Floor (mV)
undatedC1-P11.12.32.52.11.62.62.0331.53474
undatedC1-P11.72.32.22.12.92.62.31.23563
undatedC1-P12.31.82.42.32.02.42.20.63698
undatedC1-P11.61.72.12.02.31.31.8331.03576
undatedC1-P12.52.52.62.32.73.12.6170.83591
undatedC1-P11.92.52.32.62.72.62.4330.83605
undatedC1-P12.42.02.12.52.52.42.3170.53569
undatedC1-P12.82.72.52.73.02.952.7750.53608
undatedC1-P11.82.62.62.93.02.72.61.23508
undatedC1-P13.11.41.82.61.32.22.0671.83507
2026-09-26*C1-P11.92.12.21.72.03.02.151.33509
2026-09-26-eveC1-P11.41.82.41.92.42.42.051.03543
2026-09-27C1-P13.12.52.63.13.13.22.9330.73509
2026-09-30*C1-P1Not charged
2026-10-09*C1-P13.22.92.52.23.02.82.7671.03786
2026-10-09-restday0*C1-P1Rest pool
2026-10-10*C1-P1Rest pool
2026-10-11-charge*C1-P1Rest pool
2026-10-11*C1-P1Rest pool
2026-10-14-chargeC1-P1Rest pool
2026-10-14C1-P1Rest pool
2026-10-16C1-P1Rest pool
2026-10-17C1-P12.02.52.72.12.52.62.40.73520
2026-10-18C1-P12.92.82.52.42.92.92.7330.53708
2026-10-23*C1-P1Not charged
2026-10-24*C1-P1Not charged