Latest avg IR
2.65 mΩ
2026-10-18
Fleet · C1-P4 · CNHL V2 6S ~1300 Black · 1300 mAh · C1
Parallel Go: on the C1 board | In service
Rules v7: self-discharge check passed (2 mV in 9 days). Watch cleared.
Parallel Go: on the C1 board | In service · 16 storage charges
Status call 2026-10-18 · charged in parallel
Purchase — · price — · vendor —
Latest avg IR
2.65 mΩ
2026-10-18
Spread
1.2 mΩ
Go on this spread alone. Caution starts at 2.0 mΩ, watch note at 3.0 mΩ or more. The status call is separate.
Start floor
3612 mV
Floor watch 3600 mV
Last storage
2026-10-18
Low-cell gap 87 mV · rest 22.05 V · S_R 15.9 mΩ
Not a storage night
This full charge isn't the latest IR, a fleet or series mean, or a Rule B night. Its start voltage, floor, gap and rest come from the charge start and aren't shown here.
| Session | Avg (mΩ) | Spread (mΩ) | S_R (mΩ) |
|---|---|---|---|
| 2026-10-18-charge | 3.117 | 0.1 | 18.7 |
Not a parallel charge
This individual top-up is the day-0 baseline. It isn't the latest IR, a fleet or series mean, or a Rule B night.
| Night | Avg (mΩ) | Spread (mΩ) | S_R (mΩ) | Floor (mV) | Gap (mV) |
|---|---|---|---|---|---|
| 2026-10-09-restday0 | 3.167 | 0.9 | 19.0 | 3786 | 4 |
7-day rest
History
undated · Commissioned → C1-P4
Commissioned into C1-P4, its first night with measurements. Earlier catalog nights aren't in this record. The pack ID was assigned on 2026-10-08.
2026-10-09 · Rest test started · C1-P4 → C1-P4
7-day rest test cycle 1 (suspect Cell 1); day-0 = storage_end of short DX8 top-up; 7-day reading due 2026-10-16; Rules v3
2026-10-09 · Entered Rest pool · C1-P4 → C1-P4
Off every board until the 7-day reading on 2026-10-16.
2026-10-17 · Left Rest pool · C1-P4 → C1-P4
Left the rest pool under rules v6 (approved 2026-10-17): the rest pool is retired. Back in rotation at its home slot (DX8-1 Channel 2, after C1-P3) and on the C1 parallel board from its next storage night. Rest test RT-004-1 completes in place from the first reading of that storage log, if it has not flown since 2026-10-09.
Calls
undatedC1-P4
Watch
Cell1 548 [130-line charge-per-cell mAh; was mislabelled mOhm], spread 42; same shape as an undated night; keep reduced C1 current
2026-09-22C1-P4
Caution (on board, reduced current)
spread Caution (42); chronic Cell1-high fingerprint; no current ≥50; first to pull if spread ≥50 again
2026-09-26C1-P4
Pull / OFF this night
NEW Cell1 floor 3479 + imb 191 (≥150 SD) + spread 46 Caution + Cell1 IR 592 [130-line charge-per-cell mAh; was mislabelled mOhm]; escalated from an undated night Caution-on-board
2026-09-26-eveC1-P4
Caution onboard
morning SD cleared (floor 3479→3654, imb 191→50); spread 36 Go; Cell1 pack-max IR 550 [130-line charge-per-cell mAh; was mislabelled mOhm] → Caution + reduced C1 A
2026-09-27C1-P4
Caution onboard
spread 45 Caution; Cell1 pack-max IR 561 [130-line charge-per-cell mAh; was mislabelled mOhm]; floor 3603 OK (not SD); reduced C1 A
2026-10-09C1-P4
Parallel Caution (reduced current) | Watch; rest test Cell 1 cycle 1 started 2026-10-09
Rules v3: Cell1 gap >=60 mV on 2 of last 3 (last 3 = 166/49/93 mV); >=100 on 3/13. Evidence (last 2026-09-27: IR avg 2.88 spread 0.65 mOhm, S_R 17.25; floor 3603 (Cell1); low-cell gap 93 mV)
2026-10-09C1-P4
Parallel Off (Rest pool) | Watch; rest test RT-004-1, 7-day reading due 2026-10-16; not charged during test
Rest pool (owner decision 2026-10-09): off all parallel boards and not charged until the 7-day reading; returns by rest-test result under Rules v3 (PASS/BORDERLINE/FAIL + service-tier rules). Status/grouping change only, no new measurement.
2026-10-09-restday0C1-P4
unchanged (factual measurement)
rest-test day-0 measurement 2026-10-09-restday0: start floor 3786 mV (Cell1), imbalance 5 mV, low-cell gap 4 mV, rest 22.734 V; IR avg 3.167 spread 0.9 mOhm, S_R 19.0; short top-up from near storage, rest duration unknown - not evidence for/against self-discharge; 7-day reading due 2026-10-16
2026-10-17C1-P4
Parallel Go: on the C1 board | Watch (rest test RT-004-1 completes in place)
Back in rotation under rules v6 (approved 2026-10-17): the rest pool is retired. Returns to its home slot (DX8-1 Channel 2, after C1-P3) and to the C1 parallel board on its next storage night. Rest test RT-004-1 (Cell 1) completes in place from the first reading of that storage log, if it has not flown since 2026-10-09; the drop is scaled to 7 days (pass 10 mV or less, borderline 10 to 30 mV, fail over 30 mV, and a fail is a note). Watch is a note only.
2026-10-17C1-P4
Parallel Go: on the C1 board | Watch (self-discharge check RT-004-1)
Re-graded under rules v7. No pull sign in the data. The open rest test RT-004-1 (Cell 1) is now the self-discharge check: it completes from the first line of its next storage log if the pack has not flown since 2026-10-09. The low-cell gap is a performance note.
2026-10-18C1-P4
Parallel Go: on the C1 board | In service
Rules v7: self-discharge check passed (2 mV in 9 days). Watch cleared.
2026-10-18
Color scale is this snapshot only.
Every night for this pack
The line follows this pack by serial, under whatever label it had that night. Every recorded reading is joined to the next one, including charge-alone nights and nights from before a move. A night it wasn't charged, between two readings, shows as a faint dotted line with no value. Nothing is drawn before the first reading or after the last, and a pack with only its first reading is a single point. A star on the night label means a partial night, which is a separate thing.
dotted = not charged
CNHL-2026-004 per-cell internal resistance, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-17, 2026-10-23, 2026-10-24.
Rules v7
dotted = not charged
CNHL-2026-004 intra-pack spread with watch-note guides, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-17, 2026-10-23, 2026-10-24.
Watch line
dotted = not charged
CNHL-2026-004 start floor with a 3600 millivolt watch line Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-17, 2026-10-23, 2026-10-24.
All measured nights
Each night is one row. A dash means this pack wasn't charged that night. On the line chart, a faint dotted join connects the readings on either side, with no value filled in. Nothing is drawn before the first reading or after the last.
Cell, average and spread figures are in mΩ. A Rest pool night is labeled Rest pool: the pack was off every board and wasn't charged. Not charged means the pack was in service and wasn't logged that night. On the charts, a faint dotted line joins the readings on either side of that night, and that night has no value. Nothing is drawn before the first reading or after the last. A star is a partial night, which is different. Nights before this pack was commissioned aren't marked, and readings from before a move stay on this line.
| Night | Label | Cell 1 (mΩ) | Cell 2 (mΩ) | Cell 3 (mΩ) | Cell 4 (mΩ) | Cell 5 (mΩ) | Cell 6 (mΩ) | Avg (mΩ) | Spread (mΩ) | Floor (mV) |
|---|---|---|---|---|---|---|---|---|---|---|
| undated | C1-P4 | 4.4 | 3.1 | 1.7 | 2.7 | 2.9 | 2.9 | 2.95 | 2.7 | 3693 |
| undated | C1-P4 | 2.3 | 2.6 | 3.1 | 2.3 | 2.5 | 2.3 | 2.517 | 0.8 | 3604 |
| undated | C1-P4 | 2.9 | 3.2 | 2.5 | 2.7 | 2.7 | 2.5 | 2.75 | 0.7 | 3628 |
| undated | C1-P4 | 2.8 | 1.9 | 2.6 | 2.8 | 2.2 | 2.8 | 2.517 | 0.9 | 3740 |
| undated | C1-P4 | 3.2 | 3.1 | 2.8 | 3.2 | 3.1 | 2.8 | 3.033 | 0.4 | 3699 |
| undated | C1-P4 | 3.4 | 3.2 | 2.9 | 3.3 | 3.0 | 2.2 | 3.0 | 1.2 | 3630 |
| undated | C1-P4 | 2.5 | 2.3 | 2.8 | 2.8 | 2.3 | 2.6 | 2.55 | 0.5 | 3549 |
| undated | C1-P4 | 2.7 | 3.0 | 2.3 | 3.1 | 3.0 | 2.5 | 2.767 | 0.8 | 3657 |
| undated | C1-P4 | 2.9 | 3.1 | 2.9 | 3.2 | 2.6 | 3.1 | 2.967 | 0.6 | 3599 |
| undated | C1-P4 | 2.9 | 2.8 | 3.0 | 2.1 | 2.7 | 2.6 | 2.683 | 0.9 | 3640 |
| 2026-09-26* | C1-P4 | 3.0 | 1.9 | 3.0 | 3.0 | 2.4 | 2.7 | 2.667 | 1.1 | 3479 |
| 2026-09-26-eve | C1-P4 | 3.1 | 2.8 | 2.7 | 2.9 | 2.0 | 2.4 | 2.65 | 1.1 | 3654 |
| 2026-09-27 | C1-P4 | 2.8 | 3.15 | 2.8 | 3.0 | 3.0 | 2.5 | 2.875 | 0.65 | 3603 |
| 2026-09-30* | C1-P4 | Not charged | ||||||||
| 2026-10-09* | C1-P4 | Rest pool | ||||||||
| 2026-10-10* | C1-P4 | Rest pool | ||||||||
| 2026-10-11-charge* | C1-P4 | Rest pool | ||||||||
| 2026-10-11* | C1-P4 | Rest pool | ||||||||
| 2026-10-14-charge | C1-P4 | Rest pool | ||||||||
| 2026-10-14 | C1-P4 | Rest pool | ||||||||
| 2026-10-16 | C1-P4 | Rest pool | ||||||||
| 2026-10-17-charge* | C1-P4 | Rest pool | ||||||||
| 2026-10-17 | C1-P4 | Not charged | ||||||||
| 2026-10-18 | C1-P4 | 3.1 | 3.1 | 2.1 | 1.9 | 3.0 | 2.7 | 2.65 | 1.2 | 3612 |
| 2026-10-23* | C1-P4 | Not charged | ||||||||
| 2026-10-24* | C1-P4 | Not charged | ||||||||