Fleet · C1-P3 · CNHL V2 6S ~1300 Black · 1300 mAh · C1

C1-P3 · CNHL-2026-003

GO

Parallel Go | In service

Re-graded under rules v7; supersedes the Rules v3 row of 2026-10-11. Storage nights apply the pull list only, and there is no pull sign. Its 2026-10-17 log holds one reading only, no charge data (lowest cell Cell 4, its usual cell), so it has no IR reading that night. The next-night outlook uses the end of its 2026-10-11 storage run, within 0.60 V of the other C1 packs. Its earlier low-cell gaps are a performance note.

Parallel Go | In service · 16 storage charges

Status call 2026-10-17 · charged in parallel

Purchase — · price — · vendor —

Latest avg IR

2.917 mΩ

2026-10-18

Spread

1.8 mΩ

Go on this spread alone. Caution starts at 2.0 mΩ, watch note at 3.0 mΩ or more. The status call is separate.

Start floor

3703 mV

Floor watch 3600 mV

Last storage

2026-10-18

Low-cell gap 17 mV · rest 22.295 V · S_R 17.5 mΩ

History

Slot history

  1. undated · Commissioned → C1-P3

    Commissioned into C1-P3, its first night with measurements. Earlier catalog nights aren't in this record. The pack ID was assigned on 2026-10-08.

Calls

Status over time

  1. 2026-09-22C1-P3

    Ok

    spread Go (31)

  2. 2026-09-26C1-P3

    Go

    spread 32

  3. 2026-09-26-eveC1-P3

    Go

    spread 37; imb 71 not SD

  4. 2026-09-27C1-P3

    Caution

    spread 40 + floor 3578 EYE; imb 122 not SD; ON

  5. 2026-10-09C1-P3

    Parallel Caution | In service

    Rules v3: 2026-09-27 floor 3578 mV (<3600, Cell4, its usual low cell) -> CAUTION; GO if next night is clean (owner 2026-10-09). Note: Cell4 gap last 3 = 63/61/92 mV. Evidence (last 2026-09-27: IR avg 3.02 spread 1.1 mOhm, S_R 18.1; floor 3578 (Cell4); low-cell gap 92 mV)

  6. 2026-10-09C1-P3

    Parallel Caution; GO after one clean night | In service

    Caution until the next clean storage night, then Go. Monitor: Cell 4 low-cell gap over the last 3 nights = 63/61/92 mV.

  7. 2026-10-10C1-P3

    Parallel Go | In service

    Go: clean storage night on 2026-10-10; back on the C1 board. Floor 3636 mV on its usual low Cell 4 (≥3600), IR spread 0.7 mΩ, ratio 1.08. Monitor: Cell 4 gap 61/92/65 mV over the last 3 nights. Evidence (2026-10-10: IR avg 3.08 spread 0.7 mOhm, S_R 18.5; floor 3636 (Cell4); low-cell gap 65 mV; rest 22.142 V)

  8. 2026-10-11C1-P3

    Parallel Go | In service

    Rules v3: clean night 2 (floor 3707 Cell4, gap 16); C1 board Rule B 0.186 V GO. Evidence (2026-10-11: IR 2.7/3.4/3.1/3.3/2.6/2.3 mOhm, avg 2.90, spread 1.1, max/median 1.17, S_R 17.4; floor 3707 (Cell4); low-cell gap 16 mV; rest 22.324 V)

  9. 2026-10-17C1-P3

    Parallel Go | In service

    Re-graded under rules v7; supersedes the Rules v3 row of 2026-10-11. Storage nights apply the pull list only, and there is no pull sign. Its 2026-10-17 log holds one reading only, no charge data (lowest cell Cell 4, its usual cell), so it has no IR reading that night. The next-night outlook uses the end of its 2026-10-11 storage run, within 0.60 V of the other C1 packs. Its earlier low-cell gaps are a performance note.

2026-10-18

Latest cell IR

1.7 mΩ3.5 mΩ

Color scale is this snapshot only.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
C1-P3
3.1mΩ
3.1mΩ
1.7mΩ
3.5mΩ
3.1mΩ
3.0mΩ

Every night for this pack

Cell IR across nights

The line follows this pack by serial, under whatever label it had that night. Every recorded reading is joined to the next one, including charge-alone nights and nights from before a move. A night it wasn't charged, between two readings, shows as a faint dotted line with no value. Nothing is drawn before the first reading or after the last, and a pack with only its first reading is a single point. A star on the night label means a partial night, which is a separate thing.

dotted = not charged

CNHL-2026-003 per-cell internal resistance, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-17, 2026-10-23, 2026-10-24.

1.50 mΩ2.00 mΩ2.50 mΩ3.00 mΩ3.50 mΩ4.00 mΩ

Rules v7

Intra-pack spread

dotted = not charged

CNHL-2026-003 intra-pack spread with watch-note guides, milliohms Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-17, 2026-10-23, 2026-10-24.

0.00 mΩ1.00 mΩ2.00 mΩ3.00 mΩ
Watch note ≥ 2.0 mΩWatch note, look first ≥ 3.0 mΩ

Watch line

Start floor

dotted = not charged

CNHL-2026-003 start floor with a 3600 millivolt watch line Arrow keys and the night labels move between nights. A line joins every recorded reading for this pack, including nights under an earlier label. A faint dotted line joins the real readings on either side of a night this pack was not charged. No value is plotted there. Nothing is drawn before the first reading or after the last. A pack with only its first reading is a single point. A star on the night label is a partial night and is separate: a pack that was charged still has a point. Not charged: 2026-09-30, 2026-10-09, 2026-10-14, 2026-10-16, 2026-10-17, 2026-10-23, 2026-10-24.

3500 mV3600 mV3700 mV
3600 mV watch

All measured nights

Cell IR by night

1.7 mΩ4.1 mΩ

Each night is one row. A dash means this pack wasn't charged that night. On the line chart, a faint dotted join connects the readings on either side, with no value filled in. Nothing is drawn before the first reading or after the last.

Cell 1Cell 2Cell 3Cell 4Cell 5Cell 6
undated
2.9mΩ
3.1mΩ
2.9mΩ
3.5mΩ
3.1mΩ
3.9mΩ
undated
3.3mΩ
2.9mΩ
3.1mΩ
3.1mΩ
3.1mΩ
3.0mΩ
undated
2.7mΩ
3.1mΩ
2.6mΩ
3.2mΩ
2.6mΩ
2.9mΩ
undated
2.5mΩ
2.2mΩ
3.1mΩ
2.9mΩ
4.1mΩ
3.5mΩ
undated
2.3mΩ
3.1mΩ
3.0mΩ
3.1mΩ
3.2mΩ
3.1mΩ
undated
2.4mΩ
3.1mΩ
3.1mΩ
3.1mΩ
1.7mΩ
2.7mΩ
undated
2.9mΩ
3.1mΩ
3.1mΩ
3.1mΩ
2.7mΩ
2.9mΩ
undated
2.8mΩ
2.2mΩ
3.2mΩ
3.2mΩ
2.8mΩ
3.0mΩ
undated
3.2mΩ
3.0mΩ
2.6mΩ
3.0mΩ
3.2mΩ
2.9mΩ
undated
3.3mΩ
3.2mΩ
3.1mΩ
3.2mΩ
3.2mΩ
3.0mΩ
09-26*
2.9mΩ
2.6mΩ
2.3mΩ
2.9mΩ
2.0mΩ
2.7mΩ
09-26e
3.1mΩ
2.7mΩ
2.5mΩ
3.1mΩ
2.6mΩ
2.5mΩ
09-27
2.9mΩ
3.2mΩ
3.0mΩ
3.5mΩ
2.4mΩ
3.1mΩ
09-30*
—
—
—
—
—
—
10-09*
—
—
—
—
—
—
10-10*
3.1mΩ
2.9mΩ
3.2mΩ
3.4mΩ
2.7mΩ
3.2mΩ
10-11*
2.7mΩ
3.4mΩ
3.1mΩ
3.3mΩ
2.6mΩ
2.3mΩ
10-14
—
—
—
—
—
—
10-16
—
—
—
—
—
—
10-17
—
—
—
—
—
—
10-18
3.1mΩ
3.1mΩ
1.7mΩ
3.5mΩ
3.1mΩ
3.0mΩ
10-23*
—
—
—
—
—
—
10-24*
—
—
—
—
—
—
Night table

Cell, average and spread figures are in mΩ. A Rest pool night is labeled Rest pool: the pack was off every board and wasn't charged. Not charged means the pack was in service and wasn't logged that night. On the charts, a faint dotted line joins the readings on either side of that night, and that night has no value. Nothing is drawn before the first reading or after the last. A star is a partial night, which is different. Nights before this pack was commissioned aren't marked, and readings from before a move stay on this line.

NightLabelCell 1 (mΩ)Cell 2 (mΩ)Cell 3 (mΩ)Cell 4 (mΩ)Cell 5 (mΩ)Cell 6 (mΩ)Avg (mΩ)Spread (mΩ)Floor (mV)
undatedC1-P32.93.12.93.53.13.93.2331.03607
undatedC1-P33.32.93.13.13.13.03.0830.43642
undatedC1-P32.73.12.63.22.62.92.850.63478
undatedC1-P32.52.23.12.94.13.53.051.93474
undatedC1-P32.33.13.03.13.23.12.9670.93673
undatedC1-P32.43.13.13.11.72.72.6831.43596
undatedC1-P32.93.13.13.12.72.92.9670.43624
undatedC1-P32.82.23.23.22.83.02.8671.03634
undatedC1-P33.23.02.63.03.22.92.9830.63613
undatedC1-P33.33.23.13.23.23.03.1670.33622
2026-09-26*C1-P32.92.62.32.92.02.72.5670.93622
2026-09-26-eveC1-P33.12.72.53.12.62.52.750.63632
2026-09-27C1-P32.93.23.03.52.43.13.0171.13578
2026-09-30*C1-P3Not charged
2026-10-09*C1-P3Not charged
2026-10-10*C1-P33.12.93.23.42.73.23.0830.73636
2026-10-11*C1-P32.73.43.13.32.62.32.91.13707
2026-10-14C1-P3Not charged
2026-10-16C1-P3Not charged
2026-10-17C1-P3Not charged
2026-10-18C1-P33.13.11.73.53.13.02.9171.83703
2026-10-23*C1-P3Not charged
2026-10-24*C1-P3Not charged